Skip to content

FD503 material applications

Wind-turbine power controls

FD503 is an option for potting small wind-turbine control supplies. The mounting position sets the weight, vibration and service constraints.

Wind-turbine nacelle and hub above a rural landscape
Illustrative image: potential FD503 application.

Material supply

FD503 grades

Full grade comparison

FD503-TG60E

TG60E’s low viscosity helps it flow beneath small transformers in compact pitch-control supplies.

Thermal conductivity
≥0.6 W/m·K
Mixed viscosity
1,500-2,500 cps
Working time
30-50 min

FD503-TG101

TG101 is an option for a nacelle auxiliary supply where coverage, heat transfer and added mass are weighed together.

Thermal conductivity
≥0.9 W/m·K
Mixed viscosity
2,500 ± 1,000 cps
Working time
At least 30 min

FD503-TG20

TG20 is an option around hotter auxiliary magnetics. Shore 00 and Shore A have separate specifications; the printed 80°C cure entry needs confirmation.

Thermal conductivity · Shore 00
2.0 ± 0.1 W/m·K
Mixed viscosity
3,000-5,000 cps
Working time
At least 40 min

TG20 has separate Shore 00 and Shore A data sheets with different values. Confirm the version with DBSilco before ordering.

Potential potting locations

Hub pitch-drive supply
This converter powers blade-position controls while rotating with the hub. Its orientation changes as the rotor turns.
Nacelle control supply
The supply powers controllers, sensors and communication near vibrating machinery and changing internal temperatures.
Tower-base driver supply
An isolated supply powers converter switch drivers. The cabinet must retain its insulation spacing and cooling path.

Application testing

Compatibility, cure and assembly performance need testing with the production materials and process.

Pitch-cycle temperatures
Temperature tests should cover windings and switches during repeated movement and the longest planned standby period at high nacelle temperature.
Mounted vibration
The actual bracket and filled module need testing together. Inspection should look for component movement, damaged solder joints and separation from compartment walls.
Insulation and cold restart
Environmental cycling should be followed by insulation and function tests, including start-up at the specified low temperature.
More in energy