Skip to content

Technical information

Data notes and compliance documents

Some FD503 cure temperatures are missing or unclear. TG20 has two data-sheet versions; TG60S lists a flame rating without supporting test details.

Download technical data sheets

Grade-specific notes

Cure temperatures and TDS versions

Unclear cure entries need confirmation with DBSilco. The final cure schedule and assembly qualification remain with your team.

Cure entries by grade
TDS cure entries and conditions to confirm for all five FD503 grades
GradeWhat the TDS saysWhat to confirm
FD503-TG60EThe cure table lists 1–3 h at T+5°C, 3–5 h at T and 5–9 h at T−5°C, but does not define T. The description permits room-temperature or heated cure; the processing instructions specify heat.The reference temperature T and the cure schedule for your process.
FD503-TG101The TDS permits room-temperature or heated cure. Its ≤6 h entry does not state a cure temperature.The temperature for the listed cure time and the schedule for your process.
FD503-TG20The Shore 00 sheet prints ≤30 against 80°C curing time in hours. The unit and value are unclear; confirm the schedule with DBSilco. A separate ≤3 h entry has no stated temperature. The description calls for heat, while the processing instructions also permit room-temperature cure.The selected TDS version, the unclear 80°C entry and the cure schedule.
FD503-TG30The TDS permits room-temperature or heated cure. It lists ≤60 min at 80°C and a separate ≤6 h value without a stated temperature.The conditions for the separate ≤6 h entry and the schedule for your process.
FD503-TG60SThe TDS permits room-temperature or heated cure. Its 2–5 h entry does not state a cure temperature.The temperature for the 2–5 h entry and the schedule for your process.
TG20 · two data-sheet versions

The Shore 00 and Shore A sheets list different working time, hardness, thermal-conductivity tolerance, dielectric strength, volume resistivity and density. Do not combine values from the two.

Tell us which data sheet your project uses when you request trial material or a quotation.

TG60S · flame rating & thermal data

The TDS lists a V-0 (UL 94) flame-retardant rating but gives no thermal-conductivity value.

The sheet gives no report number or specimen thickness. The listed material rating does not certify a finished assembly. If your project requires flame-test evidence, specify the required grade, thickness and report scope in your enquiry.

TG60S TDS

Compliance statements in the TDS

The TDSs state RoHS compliance for all five grades and REACH compliance for TG20. Supporting report availability and scope require confirmation.

Email sales about documents
RoHS and REACH statements in each FD503 technical data sheet
GradeRoHSREACH
FD503-TG60EStated in TDSNot stated in TDS
FD503-TG101Stated in TDSNot stated in TDS
FD503-TG20Stated in TDSStated in TDS
FD503-TG30Stated in TDSNot stated in TDS
FD503-TG60SStated in TDSNot stated in TDS
Safety information
Safety data sheets for the selected grade and its A/B components. Availability is confirmed with DBSilco.
Compliance evidence
The required grade, regulation and report scope, such as RoHS or REACH. Supporting reports are subject to availability.
Batch & test information
Batch number, test property and conditions. Batch certificates, results and application reports are subject to availability.

Buy from DBSilco

Get a quote for your FD503 order.

Email the grade, quantity and delivery destination. We’ll confirm pricing, A/B pack sizes and delivery terms.

Grade not selected? Include your application and required properties.

Sales email

sales@dbsilco.com