Technical information
Data notes and compliance documents
Some FD503 cure temperatures are missing or unclear. TG20 has two data-sheet versions; TG60S lists a flame rating without supporting test details.
Download technical data sheetsGrade-specific notes
Cure temperatures and TDS versions
Unclear cure entries need confirmation with DBSilco. The final cure schedule and assembly qualification remain with your team.
Cure entries by grade
| Grade | What the TDS says | What to confirm |
|---|---|---|
| FD503-TG60E | The cure table lists 1–3 h at T+5°C, 3–5 h at T and 5–9 h at T−5°C, but does not define T. The description permits room-temperature or heated cure; the processing instructions specify heat. | The reference temperature T and the cure schedule for your process. |
| FD503-TG101 | The TDS permits room-temperature or heated cure. Its ≤6 h entry does not state a cure temperature. | The temperature for the listed cure time and the schedule for your process. |
| FD503-TG20 | The Shore 00 sheet prints ≤30 against 80°C curing time in hours. The unit and value are unclear; confirm the schedule with DBSilco. A separate ≤3 h entry has no stated temperature. The description calls for heat, while the processing instructions also permit room-temperature cure. | The selected TDS version, the unclear 80°C entry and the cure schedule. |
| FD503-TG30 | The TDS permits room-temperature or heated cure. It lists ≤60 min at 80°C and a separate ≤6 h value without a stated temperature. | The conditions for the separate ≤6 h entry and the schedule for your process. |
| FD503-TG60S | The TDS permits room-temperature or heated cure. Its 2–5 h entry does not state a cure temperature. | The temperature for the 2–5 h entry and the schedule for your process. |
TG20 · two data-sheet versions
The Shore 00 and Shore A sheets list different working time, hardness, thermal-conductivity tolerance, dielectric strength, volume resistivity and density. Do not combine values from the two.
Tell us which data sheet your project uses when you request trial material or a quotation.
TG60S · flame rating & thermal data
The TDS lists a V-0 (UL 94) flame-retardant rating but gives no thermal-conductivity value.
The sheet gives no report number or specimen thickness. The listed material rating does not certify a finished assembly. If your project requires flame-test evidence, specify the required grade, thickness and report scope in your enquiry.
TG60S TDSCompliance statements in the TDS
The TDSs state RoHS compliance for all five grades and REACH compliance for TG20. Supporting report availability and scope require confirmation.
Email sales about documents| Grade | RoHS | REACH |
|---|---|---|
| FD503-TG60E | Stated in TDS | Not stated in TDS |
| FD503-TG101 | Stated in TDS | Not stated in TDS |
| FD503-TG20 | Stated in TDS | Stated in TDS |
| FD503-TG30 | Stated in TDS | Not stated in TDS |
| FD503-TG60S | Stated in TDS | Not stated in TDS |
- Safety information
- Safety data sheets for the selected grade and its A/B components. Availability is confirmed with DBSilco.
- Compliance evidence
- The required grade, regulation and report scope, such as RoHS or REACH. Supporting reports are subject to availability.
- Batch & test information
- Batch number, test property and conditions. Batch certificates, results and application reports are subject to availability.