FD503 material applications

Vehicle onboard chargers

Local potting can surround an onboard charger’s transformer and auxiliary supply while cooling connections and insulation gaps stay clear.

Aluminum onboard charger on an engineering workbench with sealed connectors and coolant fittings.
Illustrative image: potential FD503 application.

Material supply

FD503 grades

Full grade comparison

FD503-TG60E

TG60E has a 1,500–2,500 cps viscosity for narrow auxiliary-supply passages.

Thermal conductivity
≥0.6 W/m·K
Mixed viscosity
1,500-2,500 cps
Working time
30-50 min

FD503-TG20

TG20 is a medium-viscosity option around magnetics. Shore 00 and Shore A have different hardness and other properties.

Thermal conductivity · Shore 00
2.0 ± 0.1 W/m·K
Mixed viscosity
3,000-5,000 cps
Working time
At least 40 min

FD503-TG30

TG30 lists ≥3.0 W/m·K conductivity and 8,000–15,000 cps viscosity. Its thicker mix needs accessible gaps and a clear heat path to the housing.

Thermal conductivity
≥3.0 W/m·K
Mixed viscosity
8,000-15,000 cps
Working time
At least 30 min

TG20 has separate Shore 00 and Shore A data sheets with different values. Confirm the version with DBSilco before ordering.

Potential potting locations

PFC inductor pocket
This inductor belongs to the input power circuit. Air trapped around its body or winding exits can break contact between the fill and housing.
Isolated converter magnetics
The transformer and output inductor need room for filling around their bodies. Insulation barriers and terminal exits must remain clear.
Auxiliary power supply
This separately enclosed supply powers gate drivers and control electronics. Its plug must remain accessible after filling.

Application testing

Compatibility, cure and assembly performance need testing with the production materials and process.

Charging temperatures
The thermal test should record winding, switch and housing temperatures at maximum charging load and the specified coolant limits.
Electrical isolation
Humidity and thermal cycling should be followed by the charger’s insulation tests and inspection for voids around the transformer.
Vehicle vibration
Lead exits, solder joints and contact with the housing need inspection after the specified vibration test and repeated operating cycles.
More in mobility

Buy from DBSilco

Get a quote for your FD503 order.

Email the grade, quantity and delivery destination. We’ll confirm pricing, A/B pack sizes and delivery terms.

Grade not selected? Include your application and required properties.

Sales email

sales@dbsilco.com