Skip to content

FD503 material applications

Solar microinverters

Local potting can surround a microinverter’s windings, with a heat path to the housing in its under-panel position.

Compact microinverter and cable connectors mounted beneath a photovoltaic panel on aluminum rails
Illustrative image: potential FD503 application.

Material supply

FD503 grades

Full grade comparison

FD503-TG20

TG20 is an option around magnetics and power circuits. Its Shore 00 and Shore A versions have separate sheets, and the printed 80°C cure entry needs clarification.

Thermal conductivity · Shore 00
2.0 ± 0.1 W/m·K
Mixed viscosity
3,000-5,000 cps
Working time
At least 40 min

FD503-TG30

TG30 has thermal conductivity of at least 3.0 W/m·K for hotter conversion components near the housing. Its higher-viscosity mix needs open filling gaps.

Thermal conductivity
≥3.0 W/m·K
Mixed viscosity
8,000-15,000 cps
Working time
At least 30 min

FD503-TG101

TG101 is an option for lower-loss control circuits and winding spaces where reliable filling matters most.

Thermal conductivity
≥0.9 W/m·K
Mixed viscosity
2,500 ± 1,000 cps
Working time
At least 30 min

TG20 has separate Shore 00 and Shore A data sheets with different values. Confirm the version with DBSilco before ordering.

Potential potting locations

DC input circuits
Switches and inductors handle changing panel current. They need a heat path to the enclosure’s cooling surface.
Isolation transformer
Windings and bobbins can trap air where material is hard to see. Trial samples need inspection inside those spaces.
AC output circuits
Power switches, drive supplies and sensors feed the AC output. Connectors and required pressure-relief features remain clear.

Application testing

Compatibility, cure and assembly performance need testing with the production materials and process.

Component temperatures
Input-voltage and load tests should record switch and winding temperatures in the actual mounting position.
Daily temperature changes
Complete units need the specified environmental cycles, followed by inspection for material separation, cracked joints and displaced parts.
Electrical and enclosure checks
Environmental exposure should be followed by insulation and function tests. Enclosure sealing needs its own checks, separate from material specimen data.
More in energy

Buy from DBSilco

Get a quote for your FD503 order.

Email the grade, quantity and delivery destination. We’ll confirm pricing, A/B pack sizes and delivery terms.

Grade not selected? Include your application and required properties.

Sales email

sales@dbsilco.com