FD503 material applications

AI server power supplies

FD503 grades are options for local potting around transformers, inductors and auxiliary supplies in server PSUs. Keep fan passages, connectors and service access clear.

Open server power-supply cartridge with magnetics, control board and cooling fan
Illustrative image: potential FD503 application.

Material supply

FD503 grades

Full grade comparison

FD503-TG101

TG101’s low viscosity helps the material flow around components of different heights in an auxiliary supply.

Thermal conductivity
≥0.9 W/m·K
Mixed viscosity
2,500 ± 1,000 cps
Working time
At least 30 min

FD503-TG20

TG20 is an option for hotter magnetics next to a metal cooling surface. Shore 00 and Shore A have separate specifications; cure conditions require confirmation.

Thermal conductivity · Shore 00
2.0 ± 0.1 W/m·K
Mixed viscosity
3,000-5,000 cps
Working time
At least 40 min

FD503-TG30

TG30 has thermal conductivity of at least 3.0 W/m·K. Its 8,000–15,000 cps mixed viscosity needs open filling gaps around the windings; its higher density also adds cartridge weight.

Thermal conductivity
≥3.0 W/m·K
Mixed viscosity
8,000-15,000 cps
Working time
At least 30 min

TG20 has separate Shore 00 and Shore A data sheets with different values. Confirm the version with DBSilco before ordering.

Potential potting locations

Inductors and transformers
Winding leads and insulation spacing need to remain as designed after filling.
Auxiliary supplies
Small converters power standby and control circuits inside the replaceable PSU cartridge.
Power-board compartments
A compartment beside the metal housing may provide a heat path without blocking airflow from the fan.

Application testing

Compatibility, cure and assembly performance need testing with the production materials and process.

Cartridge temperatures
Temperature tests should use the planned fan control, inlet temperature and server loads, with readings at critical components and the housing.
Electrical performance
The equipment maker’s tests should cover output voltage, load-change response, insulation and control operation on the finished PSU.
Replacement and cycling
Insertion, removal and temperature-cycle tests should be followed by checks of mounts, transformer leads and access to replaceable parts.