Skip to content

FD503 material applications

48 V rack power conversion

Local potting is an option for a 48 V rack converter’s inductors and auxiliary supplies. Busbar contacts and service connections stay accessible.

Rack bus-converter module with copper inductors, bus connections and a finned heat sink
Illustrative image: potential FD503 application.

Material supply

FD503 grades

Full grade comparison

FD503-TG101

TG101’s low viscosity helps it flow between closely spaced parts of the auxiliary supply.

Thermal conductivity
≥0.9 W/m·K
Mixed viscosity
2,500 ± 1,000 cps
Working time
At least 30 min

FD503-TG20

TG20 is an option around hotter inductors. Shore 00 and Shore A have separate specifications; their cure conditions require confirmation.

Thermal conductivity · Shore 00
2.0 ± 0.1 W/m·K
Mixed viscosity
3,000-5,000 cps
Working time
At least 40 min

FD503-TG30

TG30 is an option around windings with open filling gaps and a heat path to the housing. Its higher-viscosity mix needs enough clearance beneath the windings.

Thermal conductivity
≥3.0 W/m·K
Mixed viscosity
8,000-15,000 cps
Working time
At least 30 min

TG20 has separate Shore 00 and Shore A data sheets with different values. Confirm the version with DBSilco before ordering.

Potential potting locations

Converter inductors
Inductors in the DC/DC module need their specified lead spacing and cooling surfaces after filling.
Auxiliary supplies
Small regulators power control circuits beside the main converter. Communication sockets and adjustment points need access.
Carrier modules
A removable carrier can hold the filled converter while its busbar contacts or board-edge connector remain accessible.

Application testing

Compatibility, cure and assembly performance need testing with the production materials and process.

Electrical loading
Load and start-up tests should check output voltage, current sharing and control communication across the operating range.
Temperatures
Before-and-after temperature readings should cover switches, inductors and the carrier with the actual cooling and rack inlet conditions.
Repeated installation
Mounting and temperature-cycle tests should check connector seating and component leads. A serviced module needs to fit again without damage to the cured material.
More in computing

Buy from DBSilco

Get a quote for your FD503 order.

Email the grade, quantity and delivery destination. We’ll confirm pricing, A/B pack sizes and delivery terms.

Grade not selected? Include your application and required properties.

Sales email

sales@dbsilco.com