FD503 material applications

Network-switch power supplies

FD503 grades are options for selected circuits in a network switch’s power supply. Grade choice must account for full port loads, cooling airflow and module replacement.

Network switches with a removable power-supply cassette on a laboratory bench
Illustrative image: potential FD503 application.

Material supply

FD503 grades

Full grade comparison

FD503-TG60E

TG60E’s low viscosity helps it flow around small transformers and inductors. The TDS leaves cure temperature T undefined; contact DBSilco to confirm the schedule before production.

Thermal conductivity
≥0.6 W/m·K
Mixed viscosity
1,500-2,500 cps
Working time
30-50 min

FD503-TG101

TG101 is an option for a small fill between conversion components and the cassette wall, with the fan channel left open.

Thermal conductivity
≥0.9 W/m·K
Mixed viscosity
2,500 ± 1,000 cps
Working time
At least 30 min

FD503-TG30

TG30 has thermal conductivity of at least 3.0 W/m·K for hotter conversion components near the enclosure wall. Its higher viscosity needs open filling passages, and its higher density adds weight.

Thermal conductivity
≥3.0 W/m·K
Mixed viscosity
8,000-15,000 cps
Working time
At least 30 min

Potential potting locations

Removable AC/DC supply
The cassette holds a transformer, rectifier and power switches. Its inlet, latch and fan passage need to remain usable.
PoE power circuits
Switches and sensors control power to groups of ports. Ethernet magnetics and connectors remain outside the fill.
Standby converter
This small supply powers management functions before the main switch circuits turn on.

Application testing

Compatibility, cure and assembly performance need testing with the production materials and process.

PoE and backup supply
Temperature tests should cover windings, switches and the enclosure at full port allocation and the specified supply-failure condition.
Insulation after cycling
Temperature cycling needs to be followed by insulation tests and void inspection between the input and output circuits.
Service and airflow
Repeated cassette installation should be followed by cooling, extraction-force and contact-cleanliness checks.
More in computing

Buy from DBSilco

Get a quote for your FD503 order.

Email the grade, quantity and delivery destination. We’ll confirm pricing, A/B pack sizes and delivery terms.

Grade not selected? Include your application and required properties.

Sales email

sales@dbsilco.com