FD503 material applications

Portable power stations

Portable power stations can use FD503 in selected converter compartments, separate from cells and vents.

Portable power station on a timber camping table with its ventilation and covered output sockets visible
Illustrative image: potential FD503 application.

Material supply

FD503 grades

Full grade comparison

FD503-TG101

TG101 suits a lower-loss auxiliary converter, flowing around tall and short components and carrying heat to the housing.

Thermal conductivity
≥0.9 W/m·K
Mixed viscosity
2,500 ± 1,000 cps
Working time
At least 30 min

FD503-TG30

TG30 is an option for accessible inverter magnetics with a heat path to the carrier. Its higher-viscosity fill adds weight and needs open passages.

Thermal conductivity
≥3.0 W/m·K
Mixed viscosity
8,000-15,000 cps
Working time
At least 30 min

FD503-TG60S

TG60S is an option for a separate battery-electronics compartment.

Flame-retardant rating
V-0 (UL 94), as listed in the TDS
Mixed viscosity
600-1,200 cps
Working time
30-60 min

TG60S lists V-0 (UL 94) in its TDS. Thermal conductivity, specimen thickness and a test report are not provided. A material rating does not establish the finished assembly’s rating.

Potential potting locations

Inverter magnetics
Accessible coils or filters can be locally potted with a heat path to the metal carrier. The power switches retain their specified cooling interface.
Charging converters
These converters and support circuits handle solar or AC input. Sockets and protection components remain reachable.
Battery interfaces
A small monitoring or auxiliary-power compartment sits beside the pack. Cells, vents and temperature-sensor contact points stay clear.

Application testing

Compatibility, cure and assembly performance need testing with the production materials and process.

Charge and discharge heat
Charging and output tests should measure winding, converter and nearby battery temperatures at the specified ambient conditions.
Handling and vibration
The finished unit needs representative carrying, transport and drop tests, followed by carrier, lead-exit and fill inspection.
Outputs and battery monitoring
Socket outputs, battery readings, protection functions and standby operation need checks after cure and environmental cycling against the product’s acceptance limits.