Skip to content

FD503 material applications

Pipeline monitoring electronics

Local potting can cover a pipeline transmitter’s dry supply and communication circuits while pressure passages and calibration points stay clear.

Pipeline pressure transmitter with a blank display, valve manifold and two stainless impulse tubes
Illustrative image: potential FD503 application.

Material supply

FD503 grades

Full grade comparison

FD503-TG60E

TG60E’s low viscosity helps flow through narrow gaps in a small dry-head supply compartment.

Thermal conductivity
≥0.6 W/m·K
Mixed viscosity
1,500-2,500 cps
Working time
30-50 min

FD503-TG101

TG101 is an option around loop-output circuits when dispensing space is available and the fill stays separate from the sensor mount.

Thermal conductivity
≥0.9 W/m·K
Mixed viscosity
2,500 ± 1,000 cps
Working time
At least 30 min

Potential potting locations

Sensor-reading circuits
These circuits power the sensor, process readings and correct temperature-related errors in the dry head. Sensor mechanisms and pressure passages stay outside the fill.
Loop-powered supply
The regulator and input protection must operate with the current and voltage available through the field wiring.
Output and modem board
The current-loop output, modem and processor send readings. Setup contacts and service terminals need access.

Application testing

Compatibility, cure and assembly performance need testing with the production materials and process.

Reading accuracy
Calibrated pressure inputs should check offset and scale (zero and span), temperature correction and repeatability before and after environmental cycling.
Loop and digital messages
The specified loop supply and cable load should guide output-error, modem and start-up tests, including sensor and communication fault reporting.
Mechanical and insulation checks
Vibration and humidity tests should be followed by inspection of voids, strained wires and dry-head seals, plus repeated insulation and service-access checks.
More in field equipment

Buy from DBSilco

Get a quote for your FD503 order.

Email the grade, quantity and delivery destination. We’ll confirm pricing, A/B pack sizes and delivery terms.

Grade not selected? Include your application and required properties.

Sales email

sales@dbsilco.com