Potential potting locations
- Payload power adapters
- Regulators and protection circuits connect the aircraft supply to a removable camera or survey instrument.
- Interface boards
- These boards carry communication and control signals. High-speed cable connections, antennas and service sockets need to stay clear.
- Gimbal auxiliary circuits
- A stationary compartment may hold material around these circuits without touching bearings, motor gaps, flexible cables or the rotating mount.
Application testing
Compatibility, cure and assembly performance need testing with the production materials and process.
- Power and data
- The connected payload needs supply, communication and temperature checks during start-up and its highest planned load.
- Travel and alignment
- Gimbal and removal-cycle tests should check cable freedom, lens clearance and balance. Sensor checks must follow the maker’s original calibration procedure.
- Field conditions
- Vibration and temperature-cycle tests should use the complete housing. Connector inspection and repeated readings help reveal changes after exposure.