Skip to content

FD503 material applications

Drone charging docks

FD503 is an option for potting a dock’s charger-board compartment. The housing must carry heat away during repeated charging.

Civilian inspection drone parked in an open outdoor charging dock
Illustrative image: potential FD503 application.

Material supply

FD503 grades

Full grade comparison

FD503-TG101

TG101’s low-viscosity mix helps fill around auxiliary converters of different heights.

Thermal conductivity
≥0.9 W/m·K
Mixed viscosity
2,500 ± 1,000 cps
Working time
At least 30 min

FD503-TG20

TG20 is an option for a hotter charger compartment with filling clearance. Shore 00 and Shore A have separate specifications; cure conditions require confirmation.

Thermal conductivity · Shore 00
2.0 ± 0.1 W/m·K
Mixed viscosity
3,000-5,000 cps
Working time
At least 40 min

FD503-TG30

TG30 is an option around accessible hot magnetics near the housing, with enough clearance for its higher-viscosity mix.

Thermal conductivity
≥3.0 W/m·K
Mixed viscosity
8,000-15,000 cps
Working time
At least 30 min

TG20 has separate Shore 00 and Shore A data sheets with different values. Confirm the version with DBSilco before ordering.

Potential potting locations

Charger power boards
Converters and magnetics handle battery charging. The specified heat sink and electrical clearances need to remain effective after filling.
Auxiliary supplies
These supplies power communication, cover controls and weather instruments. Antennas and mechanical drives stay outside the fill.
Contact-control circuits
Circuits below the landing platform sense or control charging. The contacts themselves need their full movement and alignment.

Application testing

Compatibility, cure and assembly performance need testing with the production materials and process.

Charging performance
Charging tests should cover power-board temperatures, charging behavior and standby consumption at the planned ambient temperatures and intervals.
Outdoor operation
The complete enclosure needs condensation and temperature-cycle tests with its actual seals, drains, heating and cooling.
Contact and cover movement
Repeated contact engagement and cover cycles should reveal alignment problems, poor electrical contact or material interfering with movement.
More in drones

Buy from DBSilco

Get a quote for your FD503 order.

Email the grade, quantity and delivery destination. We’ll confirm pricing, A/B pack sizes and delivery terms.

Grade not selected? Include your application and required properties.

Sales email